Temperature control of Rotatory atmospheric sample dyeing machine
2022-02-24
The Sample Dyeing Machine is the key to serving the workshop and providing the first-time success rate of the dyeing machine, which directly affects the factory efficiency, product quality, cost and other issues. Let's analyze the influence of the laboratory sample dyeing machine on the temperature control performance in large-scale production. 1. Unify and calibrate laboratory small prototype thermometers and workshop production thermometers The thermometer of the laboratory sample dyeing machine is generally of the resistance sensor type, and the thermometer of the dyeing machine in some production workshops is generally a bimetal thermometer. The thermometers in the workshop are unified and calibrated. 2. The temperature control of soap cooking, reduction cleaning, etc. should imitate the workshop When proofing in many dyeing factories, the dyeing must be controlled by the sample dyeing machine, and many operations such as soap cooking and reduction cleaning are performed on electric stoves or induction cookers. , and the laboratory boiling operation, the water temperature is close to 100 ℃, then the soap cooking conditions are different, the color obtained must be different. Therefore, it is recommended that soap cooking, reduction cleaning, etc. are also operated in a separate small sample machine to achieve the uniform temperature of the small sample and the large sample.